ZY-PDM1000U-C UHF partial discharge on-line monitoring system consists of sensors, digital processing acquisition and communication unit, and background analysis software. It can realize on-line monitoring of partial discharge, temperature, and vibration of three-core cables. On-line monitoring of discharge, circulation, temperature, and vibration. The system can use CT to take power on the high-voltage side of the cable or directly connect to 220V.
Category:
High-voltage cable partial discharge, circulation, temperature online monitoring system
Keywords: online monitoring system | partial discharge detection
Product Description

System power supply voltage |
AC220 / 50, CT power |
System communication method |
Network cable / optical fiber/WIFI/4G |
System protection level |
IP66/68 |
High frequency detection |
|
Examination range |
3---30MHZ |
Continuous map |
PRPD / PRPS Atlas |
Pulse map |
Record a pulse spectrum of a power frequency period |
Synchronously |
Internal / external synchronization |
Current measurement |
|
Examination range |
0~300A,Support transient signal recording |
Fault recording |
Three-phase simultaneous wave recording, recording time 1000ms, threshold 1-300A can be set
|
Temperature measurement range |
|
Range |
-5℃~260℃ |
Vibration measurement |
|
Measuring range |
0~16g |
Protection level |
IP68 |
Intelligent detection is a major issue for the planning and construction of the ubiquitous electric power Internet of Things system by the State Grid Corporation of China. It is also a key application for solving the problem of interconnection and data sharing of the operation inspection system. It is also an important basis for the practical application of big data analysis for equipment inspection.
A transformer is a device that uses the principle of electromagnetic induction to change AC voltage. The main components are a primary coil, a secondary coil, and an iron core (magnetic core). The main functions are: voltage conversion, current conversion, impedance conversion, isolation, voltage stabilization (magnetic saturation transformer), etc. It is a key device in the power system. Generally, transformers rarely fail. Once a certain defect occurs inside the transformer equipment, equipment failure is extremely easy to occur. Therefore, strengthening and improving the operation monitoring of transformer equipment is of great significance for ensuring the safe operation of transformers.
DXK-ZY high-voltage charged display is a new type of device to prevent electrical misoperation. It is an inductive (non-contact) high-voltage charged detection device. The device has advanced design, reasonable structure, complete functions, safety and reliability. It has functions such as flashing display, audible alarm, fault self-test and activation of forced blocking circuit, etc., and has high sensitivity and reliability. This device is suitable for outdoor (also suitable for indoor) electrical network or equipment with AC 50Hz and rated voltage of 40.5 ~ 1100kV, and it is used to reflect the charged condition and prevent electrical misoperation. The device is installed on the line grounding knife switch, the bus grounding knife switch and the busbar pressure change grounding knife switch